KitchenAid
®
Model KPEC992M
900 cfm (25.5 m
3
/m) Exterior Blower
Installation Instructions and Use and Care Guide
Your safety and the safety of others
are very important.
We have provided many important
safety messages in this manual and on
your appliance. Always read and obey
all safety messages.
This is the safety alert
symbol.
This symbol alerts you to
potential hazards that can kill or hurt
you and others.
All safety messages will follow the
safety alert symbol and either the word
“DANGER” or “WARNING”. These
words mean:
All safety messages will tell you what
the potential hazard is, tell you how to
reduce the chance of injury, and tell you
what can happen if the instructions are
not followed.
You can be killed or seriously
injured if you don’t immediately
follow instructions.
You can be killed or seriously
injured if
you don’t follow
instructions.
WARNING
Before you start...
Electrical
requirements
DANGER
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
The installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future
reference and for local electrical inspectors use.
IMPORTANT: Observe all governing
codes and ordinances.
It is the customer’s responsibility:
To contact a qualified electrical
installer.
To assure that the electrical installation
is adequate and in conformance with
National Electrical Code, ANSI/NFPA
70 — latest edition*, or CSA
Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2
No.0-M91 - latest edition** and all local
codes and ordinances.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you
are not sure exterior blower is properly
grounded.
Do not have a fuse in the neutral or
ground circuit.
A.A 120-volt, 60-Hz, AC-only supply
wired for 15 amp service is required.
B.The blower motor must be
connected with copper wire only.
Copies of standards listed may be
obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Page 1
17-3/4"
(45.1 cm)
23-1/4"
(59.1 cm)
7-1/4"
(18.4 cm)
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE
THE FOLLOWING: Use this unit only
in the manner intended by the
manufacturer. If you have any
questions, contact the manufacturer.
Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a prominent warning
device, such as a tag, to the service
panel.
CAUTION: For General Ventilating Use
Only. Do Not Use To Exhaust
Hazardous or Explosive Materials and
Vapors.
IMPORTANT: Observe all governing
codes and ordinances.
Proper installation is your responsibility.
Make sure you have everything
necessary for correct installation. It is
the responsibility of the installer to
comply with the clearances specified.
To avoid damage to motor bearings
and impellers, keep drywall spray,
construction dust, etc. away from the
exterior blower.
IMPORTANT
Before installing exterior mounted
blower, read the Installation Instructions
for the vent system that will be used in
conjunction with this exterior blower.
This fan is suitable for use with solid-
state speed controls.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - B.The blower motor must be

KitchenAid®Model KPEC992M 900 cfm (25.5 m3/m) Exterior BlowerInstallation Instructions and Use and Care GuideYour safety and the safety of othersare v

Page 2 - C.The blower motor must be

Raccordementélectrique etraccordement auconduit d’aspirationInstallation du ventilateurextérieur sur un toit plat :Centre le trou de dia. 27,9 cm (11

Page 3 - Now start

SCHÉMA DECÂBLAGE Page 5Entretien duventilateur extérieur• Avant d’entreprendre une opération denettoyage ou d’entretien, interromprel’alimentation éle

Page 4 - Making electrical

Demande d'assistance ou de service aux É.-U.Téléphoner au Centre d'interaction avec la clientéle KitchenAid sans frais d'interurbain au

Page 5 - Care of your

VentingrequirementsMaximum length of vent systemDetermine the length of vent system you needWARNING — TO REDUCE THERISK OF FIRE, ELECTRIC SHOCK,OR INJ

Page 6 - For further assistance

FIGURE 1(for wallinstallations)Now start...Excessive Weight HazardUse two or more people to moveand install external blower.Failure to do so can resul

Page 7 - Modèle KPEC992M

Making electricaland ventconnectionsIf you are installing externalblower on a flat roof:Locate the 11" (27.9 cm) dia. holebetween rafters.Build a

Page 8 - Spécifications

WIRING DIAGRAMPage 5Care of yourexterior blower• Disconnect power supply and lockout service panel before cleaning orservicing.• To clean, remove cove

Page 9 - Commencement

436000497/9763391© 2005 KitchenAid® Registered trademark/™ trademark of KitchenAid, U.S.A., KitchenAid Canada licensee in CanadaPrinted in Italy10/200

Page 10 - Raccordement

KitchenAid®Modèle KPEC992M Ventilateur extérieur 25,5 m3/m (900 cfm)Instructions d’installation et guide d’utilisation et d’entretienVotre sécurité et

Page 11 - Entretien du

Détermination de la longueurnécessaire du circuitPour déterminer la longueur équivalentedu circuit d’aspiration nécessaire, noter lalongueur équivalen

Page 12 - Pour plus d’assistance

Risque de poids excessifUtiliser deux ou plus de personnesdéplacer et installer la hotte.Le non-respect de cette instructionpeut causer une blessure a