Note: Refer to the table on page 6 to ensure the correct
type of injector is to be fitted.
Traditional burners (T)
1. Remove the cap (A).
2. Remove the spreader (B).
3. Unscrew the injector (C) with a box spanner 7.
4. Replace the injector with the one for the new gas.
5. Put back burners and pan supports.
Note: Before installing the hob, please remember to stick
the gas calibtration label, provided with the replacement
injectors over the gas information on the underside of the
hob.
Replacing the injectors
12
A
B
C
Regulating the minimum flow level must be done with the tap at the
lowest position (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the control
knob and adjust the screws found on the tap as follows:
1. tighten to reduce the height of the flame 1 (-)
2. slacken to increase the height of the flame (+);
3. With the burners on, rotate the buttons from the maximum to
the minimum position to check the stability of the flame.
Regulating the minimum flow level of the gas taps