KitchenAid KHSP5 86510 Instruction for Use Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
Hood and cabinetry clearances (mm)
6
Note: If the distance “A” between the wall cupboards in the kitchen is
between 600mm and 730mm, the height “B” must be at least 530mm.
If the distance “A” between the wall cupboards is greater than the
width of the hob, the height “B” must be at least 400 mm.
840
+1
0
490
+1
0
R 12
860
510
74
N.B. For the semi-flush mount version
the 1.5 mm milling is not necessary.
Category
II2L3B/P
Electric supply:220-240 V ~ 50/60 Hz 0,6W
Injectors table
Type of gas used
Ty p e o f
burner
Injector
marketing
Nominal heat
flow kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min. nom. max.
NATURAL GAS
(Methane) G25
2 ring
Inner
134+71
71
6,00
0,80
664 l/h
89 l/h
1,50
0,30
20 25 30
rapid 130 3,00 332 l/h 0,70
semi-rapid 100 1,75 194 l/h 0,40
auxiliary 78 1,00 111 l/h 0,30
LIQUEFIED GAS
(Butane) G30
(Propane) G31
2 ring
Inner
80+46
46
6,00
0,80
436 g/h
58 g/h
1,50
0,30
25 30 35
rapid 85 3,00 218 g/h 0,70
semi-rapid 66 1,75 127 g/h 0,40
auxiliary 50 1,00 73 g/h 0,30
Type of gas used
Model configuration
5 burners 2C 4,8kW
Rated thermal flow rate kW Total rated consumption
Air required (m
3
) for burning
1 m
3
of gas
G25 20 mbar 2C-1R-2SR -1AUX 13,50 1495 l/h 8,187
G30/G31 30 mbar 2C-1R-2SR -1AUX 13,50 981 g/h 30,94
Page view 5