KitchenAid 740-0781 Instruction Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
15
GAS CONVERSIONS
Gas Con
nection to Natural Gas
This in
stallation must conform with local codes and ordinances. In the
absence of local codes, installations must conform with either the
National Fuel Gas Code ANSI Z223.1 - latest edition, or CAN/CGA-
B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protec
tion Association
One Batterymarch Park
Quincy, Massachusetts 02269
IMPORTANT: The Natural gas Conversion Kit supplied with this grill
must be used.
1. Turn off all burner control valves.
2. Turn off the main gas supply valve.
3. Disconnect 20 lb LP gas fuel tank (if present) and remove the 20 lb
LP gas fuel tank from the grill cabinet.
4. Use a Phillips screwdriver to remove the one-piece brass clamp
mounting bracket from the cabinet wall.
5. Use an adjustable wrench to remove the LP gas pressure regulator/
hose assembly from the 90° brass adapter.
6. Install the Natural gas pressure regulator onto the flexible gas hose
from the grill.
7. Check that the Natural gas pressure regulator is positioned under the
grill (as shown in the following illustration) and is not pinched or
kinked.
8. Use 4 screws to attach the Natural gas pressure regulator to the back
of the enclosure.
1. Make gas connections.
A combination of pipe fittings must be used to connect the grill to
the existing gas line.
Ŷ
The 10 ft (3.0 m) PVC flexible gas sup
ply hose design-certified
by CSA must be used.
Ŷ
Pipe-joint compounds suitable for use with
Natural gas must be
used. Do not use Teflon
®†
tape.
2. Connect the brass connector on one
end of the 10 ft (3.0 m) PVC
flexible gas supply hose (supplied) to the Natural gas pressure
regulator (A).
A. 2 scre
ws
B. one-piece brass clamp mounting bracket
A. Flexible gas hose fr
om grill
B. 90° brass adapter
C. LP gas pressure regulator/hose assembly
A. Natural gas pressure regulator
B. Four 5/32" x 10 mm truss head screws
B
A
C
†®TEFLON
is a registered trademark of E.I. Du Pont De Nemours and Company.
A
B
B
A
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
Install a shut-off valve.
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 95 96

Comments to this Manuals

No comments